Stamisol Safe One Technology

What makes it so special in terms of fire resistance?

Installation of facade breather membrane Class A2 Stamisol Safe One

3D network structure

This high-tech facade breather membrane has been designed and manufactured to give a specific composition of stability and durability ensuring a very high standard of fire safety to Euroclass A2-s1,d0. Its structure is based on a glass textile, which is naturally non-combustible and offers a high resistance to fire and mechanical stresses over its lifetime.
The elastomeric coating layer completes the fire resistance with a very high grade of constancy and stability because of its vulcanised 3D network structure, which, through its unique manufacturing process, ensures a Euroclass A2 specification that does not loose its composition in times of fire. This structure means its bonds are far stronger than traditional polymeric membranes.

Excellent membrane performance + maximum fire safety

For added strength and durability, the elastomeric coating is reinforced with inert mineral compounds, which maintain the limited combustibility required for a Euroclass A2 membrane.
The process of adding all these materials not only gives the product its A2-s1,d0 classification, but also the performance of a flexible membrane that is water resistant W1, breathable, UV protected and meets low mechanical damage when compared with other vertical wall membranes. It also provides a high UV standard of protection for the building where fitted.

Further topics

Learn more about maximum fire safety and creativity for your full façade system with Stamisol Safe One façade breather membrane Eurolass A2-s1,d0

Stamisol Safe One - The Technology

Download Whitepaper

>>>Please download our new Whitepaper with full technical documentation for realisation of external wall systems completly in Euroclass A2 with Stamisol Safe One façade breather membranes.

Download Whitepaper Stamisol Safe One

Stamisol Safe One - The Technology

Download
Tech Guide

>>> Please download our Technical Guide Stamisol Safe One for full information on construction models and what you should care about design and planning.

Download Technical Guide Stamisol Safe One



DCE CPD Webinar September

Please join our next CPD webinar: Learn about the difference between a Class A2 - W1 and a A1 - W2 membrane, in terms of fire safety and water tightness, as part of a façade system I Which certificates and tests are essential for your façade project?

The Webinar is scheduled for 25th of September / 14.00 - 15.00

https://www.directcontactexhibitions.com/online-cp...

DCE CPD Webinar SeptemberPlease join our next CPD webinar: Learn about the difference between a Class A2 - W1 and a A1 - W2 membrane, in terms of fire safety and water tightness, as part of a façade system I Which certificates and tests are essential for your façade project?The Webinar is scheduled for 25th of September / 14.00 - 15.00https://www.directcontactexhibitions.com/online-cp...
DCE CPD Webinar SeptemberPlease join our next CPD webinar: Learn about the difference between a Class A2 - W1 and a A1 - W2 membrane, in terms of fire safety and water tightness, as part of a façade system I Which certificates and tests are essential for your façade project?The Webinar is scheduled for 25th of September / 14.00 - 15.00https://www.directcontactexhibitions.com/online-cp...

Why use a breathable façade membrane

The protective shield for closed and open rear-ventilated façades:
— Ensures dry and functional thermal insulation and protects from deterioration
— No cooling down of the insulation by wind/air
— Building moisture is led to the outside

Read more...

Why use a breathable façade membraneThe protective shield for closed and open rear-ventilated façades: — Ensures dry and functional thermal insulation and protects from deterioration— No cooling down of the insulation by wind/air— Building moisture is led to the outsideRead more...
Why use a breathable façade membraneThe protective shield for closed and open rear-ventilated façades: — Ensures dry and functional thermal insulation and protects from deterioration— No cooling down of the insulation by wind/air— Building moisture is led to the outsideRead more...

The first façade membrane A2-s1,d0

Stamisol Safe One expands the design freedom for architects in creating facades with maximum fire safety:
— Life-saving membrane by being Euroclass A2-s1,d0
— Resistance to water penetration W1
— Excellent UV resistance, ideal for both open and closed façades

Read more...

The first façade membrane A2-s1,d0Stamisol Safe One expands the design freedom for architects in creating facades with maximum fire safety: — Life-saving membrane by being Euroclass A2-s1,d0— Resistance to water penetration W1— Excellent UV resistance, ideal for both open and closed façadesRead more...
The first façade membrane A2-s1,d0Stamisol Safe One expands the design freedom for architects in creating facades with maximum fire safety: — Life-saving membrane by being Euroclass A2-s1,d0— Resistance to water penetration W1— Excellent UV resistance, ideal for both open and closed façadesRead more...
New

Warranty

Stamisol Safe One is a hightech façade membrane with uncompromising Swiss made-quality from the Serge Ferrari Group, which offers a comprehensive 10 year warranty. Stamisol Safe One also comes with a lifetime guarantee as a Euroclass A2-s1,d0 membrane.

Read more...

WarrantyStamisol Safe One is a hightech façade membrane with uncompromising Swiss made-quality from the Serge Ferrari Group, which offers a comprehensive 10 year warranty. Stamisol Safe One also comes with a lifetime guarantee as a Euroclass A2-s1,d0 membrane.Read more...
WarrantyStamisol Safe One is a hightech façade membrane with uncompromising Swiss made-quality from the Serge Ferrari Group, which offers a comprehensive 10 year warranty. Stamisol Safe One also comes with a lifetime guarantee as a Euroclass A2-s1,d0 membrane.Read more...